HSW Mini Specifications |
Unit of Measurement |
CW-AH01
Air - 2500A 7.5V / 7%
|
CW-WH01
Water - 2500A 7.5V / 10% |
|
Max welding output voltage (Max load) |
Volt |
7.5 |
7.5 |
Max output current (Peak value) |
Ampere |
2500 |
2500 |
Instant power |
W |
18750 |
18750 |
Continuous duty cycle |
% |
7 |
10 |
Short term (10 cycles) duty cycle |
% |
15 |
15 |
Peak primary current required |
A/ac |
54 |
54 |
Minimum primary current requirement |
A/ac |
25 |
16 |
Adjustment precision (In line conforming with EN50160) |
% |
2 |
2 |
Number of welding profile phases |
each |
3 |
3 |
Max time for each phase |
Ms |
2000 |
2000 |
Number of transformers incorporated in ferrite E70 |
each |
2 |
1 |
Working frequency on the primary stage |
kHz |
15 |
15 |
Working temperature |
°C |
30 |
40 |
Interface RS232 |
|
Present |
Present |
Short circuit protection |
|
Present |
Present |
Overheating protection |
|
Autolimit |
Autolimit |
Phase loss detection |
|
Present |
Present |
Graphic memorization A + V real time |
|
Present |
Present |
Mains voltage |
Vac |
400 |
400 |
Mains frequency |
Hz |
50 - 60 |
50 - 60 |
Cos § |
|
1 |
1 |
|