DC & DCR - Technical Specifications
Switch-mode Rectifiers for Plating > DC & DCR > Technical Specifications
Previous | Next
ELECTRICAL SPECIFICATIONS
 
Q100 model
Q300 model
Q500 model
Output
Power DC
Up to 8kW
Up to 32kW
(Max 3 power modules)
Up to 110kW per tower
(Max 9 power modules)
DCR
Up to 4kW
Up to 20kW
(Max 1 reverse module)
Up to 100kW per tower
(Max 3 reverse modules)
Voltage DC
5 - 450VDC standard
DCR
5 - 50VDC standard
Operation Mode
Current Control or Voltage Control
Control accuracy
1/1000 of max current or voltage
Precision
99% on entire range
Current regulation range
5 - 100% of max current (On Request 2% Available)
Voltage regulation range
10 - 100% of max voltage (On Request 5% Available)
No voltage regulation without load
Current ripple (RMS)
< 2.0% of rated output current in current operation mode (< 1.0% on Request)
Efficiency
87% (typ.) @ rated load / 92% (for >= 160VDC) @ rated load
Regulation speed
10 - 90% in 250ms with 100ms reverse dead time
Secondary withstand voltage
50VAC 50Hz 1min. between Secondary to Earth
Pole to be connected to ground
Positive
Main
Supply
Line voltage
3 x 230VAC ± 10%, 3 x 400VAC ± 10%, 3 x 440VAC ± 10%,
3 x 480VAC ± 10% or 3 x 550VAC ± 10% or 3 x 600VAC ± 10%
Frequency
50 - 60Hz
Neutral
NOT USED
Power factor
> 93% @ rated load
Primary current
Max 20A
Max 55A
Max 230A per tower
Earth leakage current
See EMC filter input specifications
 



GENERAL SPECIFICATIONS
 
Q100 model
Q300 model
Q500 model
Technology
Switching mode PWM, Full Bridge IGBT inverter
Cooling Systems
Air
Water
Operation
Conditions
Location
Indoor use only
Ambient temperature
0 - 40°C
Relative humidity
15 - 85% not condensing
Filter obstruction - air cooled
15% max
Water input temp. - water cooled
19 - 22°C | (rectifier rev. A1-A49) | 19 - 28°C (rectifier rev. A50 or above)
Altitude
<= 2000m
Degree of Protection
Air cooled
IP31
IP21 (on request NEMA12)
IP32
Water cooled
IP43
 
IP42 (on request IP65)
Conformity of EU Directives
2006/95/EC - Low Voltage Directive
2004/108/EC - Electromagnetic Compatibility
 



SERIAL INTERFACE
Communication Ports
RS232
RS485
Communication Protocols
CRS-ASCII RS232 point-to-point and RS485 network
Modbus-RTU RS232 point-to-point and RS485 network
Profibus-DP (On request) Profibus-DP network
DeviceNet (On request) CAN bus network
Modbus/TCP Ethernet
Profinet Ethernet
EthernetIP Ethernet
 



PROTECTION
Surge
According to Directive EN 61000-4-5
2kV between each input phase and PE. 1kV across each input phase combination.
Phase Loss
Type Hardware Software
Programmed limit Half cycle Adjustable via configuration parameter
 
Output Short Circuit
Type Software
Programmed limit 25% of Iout_max
Detection Time 1ms
Thermal Protection
With PTC on each module
 



FULL LOAD HARMONICS DISTORTION
Harmonic
Freq. (Hz)
Absorbed Current Distortions
 
3
150
-
 
5
250
< 22.5%
 
7
350
< 12.5%
 
9
450
-
 
11
550
< 11.0%
 
13
650
< 7.6%
 
17
850
< 8.0%
 
19
950
< 4.8%
 
THD
MAX 30%
 
 




Last update: Oct/18/2013