The V700 is a modular full-bridge switch-mode rectifier with a 3-phase input and floated output poles; part of our Vega lineup. It can output up to 168 kW in one enclosure with up to seven modules stacked vertically, working in parallel for enhanced reliability and easier service from the front. However, if needed, the rectifiers can be interconnected to sum up their total output power. It comes in either water- or air-cooled. Manual or automatic control is possible, which allows programming waveforms, monitoring Ah, and more. A bipolar synchronized rectification enables each module to reverse its output and produce pulsed waveforms with excellent efficiency.
V700
High current scalable tower platform
UP TO 10,5 kA

- Space saving
- High power for production lines
- Water flow sensor included
- Manual or automatic controlled
- Ah counter, ramp software and more
- Ease of service
- Expandable for more power
- Pulse plating available
- Reverse polarity (on each module)
- Floating output poles
MAIN VOLTAGE (3 PHASE)
208 / 230 / 400 / 440 / 480 / 575 VAC
± 10% / 50 - 60 Hz
MAX. OUTPUT POWER
168 kW
MAX. OUTPUT VOLTAGE
6 - 400 VDC
MAX. OUTPUT CURRENT
100 - 10500 A DC
CURRENT RIPPLE
<3% (<1% on request)
OPERATION MODE
Current or voltage control
CURRENT REGULATION RANGE
2 - 100%
VOLTAGE REGULATION RANGE
5 - 100%
ACCURACY
1% of full scale
POWER FACTOR
>0.92 @ rated load
EFFICIENCY
89 - 94% @ rated load
COLOR
RAL 3004
COOLING
Air and Water
DEGREE OF PROTECTION
IP32 Air cooled
IP54 Water cooled
WEIGHT
50 - 428 kg
AMBIENT TEMPERATURE
40ºC (up to 50ºC on request)
INPUT WATER COOLING TEMPERATURE
19 - 35ºC (up to 40ºC on request)

No cabinet options available for this model.
DC HIGHER EFF
Improved efficiency by utilizing synchronous rectification technology to minimize losses. Modules under 16V can see efficiency gains of up to 6 percentage points. These benefits can also be seen with higher voltage modules operating at lower voltages, improving the full range of the efficiency curve.
REVERSE POLARITY
Allows switching the output between forward and reverse polarity.
1MS PULSE
This function is available when rise and fall times faster than 1 second are critical for the production process. Done by a combination of software and a selection of electrical components. Recipe patterns can be followed by controlling the CPU to achieve a rise time and fall time of 1ms with no overshoot when using resistive loads.
AUX POWER FOR THE CPU
An input to supply power directly to the CPU that enables continuous communication and monitoring in case the primary power is disconnected. A 24 Vdc input is included; an added internal power supply is required if a single-phase input is needed.
LOWER RIPPLE
Reduces the DC ripple to < 1%.
UL COMPLIANCE
Certain components are changed to meet UL standard compliance.
E-STOP
The E-Stop system can be configured to cut the output power of the rectifier. Complies with international standards IEC 62061 SIL Level 3 Protection and ISO 13849-1 Protection Level E. The E-Stop of rectifiers can be interconnected for simultaneous emergency activation when necessary to ensure operational safety. The E-Stop can be activated by peripheral devices when emergency conditions are detected. It is possible to configure for automatic or controlled reset.
COMM. PROTOCOLS
A wide range of industrial communication standards via a certified HMS AnyBus IC. Communication protocols are not CPU software dependent and are interchangeable with ease. The Data Map structure is not communication protocol dependent, allowing for simplified system integration. Optional communication protocols: Profibus-DP, DeviceNet, EthernetIP, Profinet, Modbus-TCP.
ANALOGUE INTERFACE
Allows for the control of the rectifier with an analogue PLC.
MULTI-TOWER CONNECTION
This function is available when rise and fall times faster than 1 second are critical for the production process. Done by a combination of software and a selection of electrical components. Recipe patterns can be followed by controlling the CPU to achieve a rise time and fall time of 1ms with no overshoot when using resistive loads.
OPERATING TEMP
Operating ambient temperatture up to 50 C with derating.
SOLENOID
An optional installation accessory that can be used to segregate the incoming water flow of the system. Prevents condensation when the rectifier is not in operation. It is not available when using the integrated Water to Water Heat Exchanger.
Remote Control
Remote control REM8E, 24VDC / 24VAC
Remote control REM8 that includes analog/digital input and output ports REM8, 85-264VAC.
REMMTV
Portable equipment to adjust and perform functional tests of the CTRL and CPU cards for Vega.
RSM09A
Quasar and Vega simulator (with CPU090 and 4-line display).
